Sign In | Join Free | My burrillandco.com
Home > Liquid Chromatography Instrument >

Binary HPLC High Performance Liquid Chromatography Instrument System High Pressure

    Buy cheap Binary HPLC High Performance Liquid Chromatography Instrument System High Pressure from wholesalers
     
    Buy cheap Binary HPLC High Performance Liquid Chromatography Instrument System High Pressure from wholesalers
    • Buy cheap Binary HPLC High Performance Liquid Chromatography Instrument System High Pressure from wholesalers
    • Buy cheap Binary HPLC High Performance Liquid Chromatography Instrument System High Pressure from wholesalers
    • Buy cheap Binary HPLC High Performance Liquid Chromatography Instrument System High Pressure from wholesalers
    • Buy cheap Binary HPLC High Performance Liquid Chromatography Instrument System High Pressure from wholesalers

    Binary HPLC High Performance Liquid Chromatography Instrument System High Pressure

    Ask Lasest Price
    Brand Name : Wayeal
    Model Number : LC3200
    Certification : ISO, CE
    Price : Negotiation
    Payment Terms : L/C, T/T
    Supply Ability : 30 Pieces Per Month
    Delivery Time : 30 days
    • Product Details
    • Company Profile

    Binary HPLC High Performance Liquid Chromatography Instrument System High Pressure

    Binary High Pressure Gradient System for HPLC High Performance Liquid Chromatography System
    Introduction of Liquid Chromatography Instrument

    High-performance liquid chromatography (HPLC; formerly referred to as high-pressure liquid chromatography), is a technique in analytical chemistry used to separate, identify, and quantify each component in a mixture.

    It relies on degas-unit and two pumps to pass a solvent referred to as a “ mobile phase” (e.g. water, acetonitrile, methanol etc.) and sample mixture through a column referred to as a “ stationary phase” filled with a solid adsorbent material, is typically a granular material made of solid particles (e.g. silica, polymers, etc.). Each component in the sample interacts slightly differently with the adsorbent material, causing different flow rates for the different components and leading to the separation of the components as they flow out the column.

    Parameters of Liquid Chromatography Instrument

    Manufacturer:Wayeal
    Product Name:Liquid Chromatography Instrument
    Working Power Supply220V, 50Hz
    Ambient Temperature10~40°C
    Relative Humidity20~85%
    Qualitative Repeatability≤0.2%
    Quantitative Repeatability≤0.4%
    High Pressure Constant Flow Pump
    Flow Rate Range0.001~10.000mL/min
    Setting Step0.001mL/min
    Pressure Range0~42MPa
    Pressure Pulsation0.1MPa
    Flow Rate Set Error±0.2%
    Flow Rate StabilityRSD≤0.06%
    Gradient Error±1%
    Column Oven
    Temperature Control Range4~85°C
    Temperature Stability±0.02°C
    Temperature Setting Resolution0.1°C
    Autosampler
    Injection Volume Repeatability<0.5%RSD
    Linearity>0.9999
    Cross Contamination<0.002%
    Injection Volume Accuracy Error±1%
    Sample Positions120
    Injection Volume1~100μL
    UV Detector
    Baseline Noise≤2.0*10-6Au
    Baseline Drift≤1*10-5Au/h
    Mini Detection Concentration≤3.0*10-9g/mL (naphthalene/methanol)
    Spectral Range188~900nm
    Wavelength Error≤±0.1nm
    Wavelength Repeatability≤±0.1nm
    Linearity Range≥103
    DA Detector
    Baseline Noise≤4*10-5Au
    Baseline Drift≤3*10-5Au/h
    Mini Detection Concentration≤2*10-8g/mL
    Spectral Range190~800nm
    Wavelength Error≤±0.1nm
    Wavelength Repeatability≤±0.1nm
    Linearity Range≥ 104
    ELS Detector
    Baseline Noise≤ 0.0037mV
    Baseline Drift≤ 0.0026mV/30min
    Evaporation Gas Flow Range(0 ~ 3) SLM
    Atomization Temperature RangeRoom temperature ~ 90℃
    Evaporation Temperature RangeRoom temperature~110℃
    Detection Chamber Temperature RangeRoom temperature~60℃
    Input Air Pressure(4 ~ 7) bar
    FL Detector
    Baseline Noise≤ 5×10-6 FU
    Baseline Drift≤ 2 × 10-5 FU/30min
    Spectral Range(200 ~ 650) nm
    Wavelength Error± 0.1 nm
    Linearity Range≥ 104
    RI Detector
    Detection Range0.25 ~ 512 μRIU
    Linearity Range≥ 600 μRIU
    Response Time0.1, 0.25, 0.5, 1, 1.5, 2, 3, 6 sec;
    Cell Volume8μL

    Application of Helium Leak Detector
    Food, medicine, environment, agriculture and scientific research.





    Quality Binary HPLC High Performance Liquid Chromatography Instrument System High Pressure for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Anhui Wanyi Science and Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)